ATA Bus Interface and ATA Commands

6-8

Maxtor D540X-4K 20.4/40.0/60.0/80.0 GB AT

determined from the information returned from the IDENTIFY DEVICE command.
Where the entry is none, the default setting must be determined by other analytical
means or by asking a trusted human source. The last column shows the default setting
(enabled or disabled) for each supported feature.

6CDNG  

Supported Features



/CZVQT 5RGEKHKE %QOOCPFU

The drives support the following Maxtor specific commands:

• READ DEFECT LIST

• READ CONFIGURATION

• SET CONFIGURATION

 4'#& &'('%6 .+56

The READ DEFECT LIST command enables the host to retrieve the drive’s defect
list. Prior to issuing this command the host should issue the READ DEFECT LIST
LENGTH command. This command will not transfer any data. It instead, stores the
length in sectors of the defect list in the Sector Count register (1F2), and the Sector
Number register (1F3), with the Sector Count register containing the LSB of the 2-
byte value (see Table 6-3). The defect list length is a fixed value for each Maxtor
product and can be calculated as follows:

length in sectors = (((maximum number of defects) * 8 + 4) + 511)/512

At the completion of the command, the task file registers 1F2 – 1F6 will contain bytes
necessary to execute the READ DEFECT LIST command, and the host will only
need to write the extended command code (F0h) to the Command register (1F7) to
proceed with the READ DEFECT LIST command execution.

'PCDNG

&KUCDNG

(GCVWTG PCOG

+& 9QTF

&GHCWNV

02h

82h

Write cache

88 bit 5

02h

03h

na

Set transfer mode

63, 88

03h

42h

C2h

Automatic Acoustic Management
feature set

86 bit 9,
94

42h

55h

AAh

Read look-ahead feature

85 bit 6

55h

CCh

66h

Reverting to power-on defaults

None

CCh