4221 Condor Hardware Installation Procedures

15

Board Status LEDs

LEDs 1, 2, 3, and 4 are Board Status LEDs which provide the following functions:

Power On Self Test (POST) Mode

Monitor Mode

Run Mode

POST Mode: This mode provides diagnostics for the CPU and Buffer. Refer to the following table for a list
of diagnostics performed while in this mode:

Table 2-3. Board Status Diagnostics Used In POST Mode

Monitor Mode: In this mode, LEDs will sequentially flicker when Serial Port A is active and the onboard
monitor is controlling the Condor.

Run Mode: When in this mode, the Condor is accepting commands from the host. Refer to the following
table for a list of LED definitions while in this mode:

Hex Code

Diagnostic

Definition

Type of Test

0x01

CPU Register Test

CPUFAIL

CPU Core Test

0x02

ROM Checksum

ROMFAIL

CPU Core Test

0x03

Walking 1’s SRAM

STAT1FAIL

CPU Core Test

0x04

Walking 0’s SRAM

STAT0FAIL

CPU Core Test

0x05

Decrementing Longwords

STATLFAIL

CPU Core Test

0x06

Word Access

STATWFAIL

CPU Core Test

0x07

Byte Access

STATBFAIL

CPU Core Test

0x08

Reserved

RESERVED

CPU Core Test

0x09

Walking 1’s In Buffer

BUFFERFAIL1

Static Buffer Test

0x0A

Walking 0’s In Buffer

BUFFERFAIL0

Static Buffer Test

0x0B

Decrementing Longwords

BUFFERFAIL

Static Buffer Test

0x0C

Walking 1’s, 0’s VME DMA

VMEFAIL

Control Register Access

0x0D

Motherboard FEC Tests

FEC0 & 1

Control Register Access

0x0E

Daughter Card FEC Tests

FEC2 & 3

Control Register Access