Chapter 3 - MACSI Host Interface

74

Controller Initialization Block (CIB)

The CIB contains the actual values to use when initializing the controller. It may be located anywhere in Short I/O,
though it makes sense to place it after the MCE and before the Command Response Block.

Table 3-20. Controller Initialization Block

Number of CQE Entries

This field specifies the number of Command Queue entries to be used in the circular queue. Without using offboard
IOPBs, the maximum number ranges between 30 and 37. With offboard CQEs, this number can be increased to 151
(1812 / 12). Choosing the correct value is important to ensure maximum performance of the controller.

Controller Initialization Block

Offst

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

0x00

Reserved

Number of CQE Entries

0x01

Special Network Options

0x02

Reserved

0x03
to
0x05

Ethernet Physical Address (Port 0)

(6 Bytes)

0x06
to
0x08

Ethernet Physical Address (Port 1)

(6 Bytes)

0x09
to
0x0B

Ethernet Physical Address (Port 2)

(6 Bytes)

0x0C
to
0x0E

Ethernet Physical Address (Port 3)

(6 Bytes)

0x0F

Controller Completion Level

Controller Completion Vector

0x10

Controller Error Level

Controller Error Vector

0x11

DMA Burst Count

0x12

Reserved

0x13

Offboard CRB Transfer Word

0x14

Offboard CRB Host Address (MSW)

0x15

Offboard CRB Host Address (LSW)

Advertising