Maintenance

Croma24 Service Manual

3.

Place the test cartridge upright on a flat surface and ‘zero’
the gauge by loosening the knob near the top and turning the
dial until the needle is at the ‘0’ position on the dial. Tighten
the knob. See Figure 3-18.

Figure 3-18. Zeroing the Micrometer Gauge.

4.

Remove the Cyan ink cartridge. Snap the test cartridge with
the micrometer gauge into the position vacated by the Cyan
ink cartridge. See Figure 3-19. Ensure that the micrometer
can be read from the BACK of the printer.

Figure 3-19. Test Cartridge Installed.

5.

Remove the trailing cable assembly.

6.

Loosen the three screws located on the back of the C-bracket
that secures the stabilizer to the C-bracket.