Ice Frost Operator’s Manual

Publication Number: M620919596OPR

- 10 -

© 2004-2006, IMI Cornelius Inc.

Setting COLD Timer (Night Setting)

1.

Turn the power switch ON. Make sure the “AUTO TIMER” is OFF (light on button is not lit).

2.

Press the left hand “Auger ON/OFF” button ON.

3.

Press and hold the “PRESS TO SELECT FUNCTION” button until you hear a long beep and the

LED, “Cold” and the “AUTO TIMER” clock light begins to blink.

4.

Press the “AUTO TIMER” clock button to set the unit to COLD mode and then press the “PRESS TO

SELECT FUNCTION” button to save the setting.

5.

Press the “AUTO TIMER” clock button to set the minutes to complete time setting that you want it to

turn to COLD mode. Then press the “PRESS TO SELECT FUNCTION” button to save the minute
setting. The “COLD” light will turn off and the “FROZEN” light and “AUTO TIMER” light will begin
blinking.

6.

Set the time you want the machine to return to FROZEN mode by following steps 1 - 5 above. Then

press the “PRESS TO SELECT FUNCTION” button to save the time settings. The FROZEN light
should be blinking.

7.

Repeat steps 1 - 6 for the opposite bowl using the left buttons.

NOTE: Once the settings have been saved, the unit will keep the settings, even when the power
switch is turned OFF.

NOTE: When the light on the “AUTO TIMER” clock button is “ON”, the COLD timer is activated. To
turn OFF the COLD timer, press the “AUTO TIMER” clock button(s) until the light(s) on the clock
button(s) turns off.

Operate in Automatic Mode (with COLD Timer Activated)

1.

Turn power switch ON and wait for LED display to light up.

2.

Press the left hand “Auger ON/OFF” button ON.

3.

To operate in COLD mode press the “AUTO TIMER” button until it is illuminated.

4.

When setting automatic times, please keep in mind it will take time for the frozen product to become

liquid or vice versa.

Operate in Manual Mode (without COLD Timer Activated)

1.

Turn the power switch ON and wait for LED display to light up.

2.

Make sure the clock button is OFF (LED light on clock button should not be lit up).

3.

First turn auger ON by pressing the “Auger ON/OFF” button until it beeps.

NOTE: The auger must be ON before the unit will allow the COLD or FROZEN mode to be
activated.

4.

Then select COLD or FROZEN mode by pressing the “PRESS TO SELECT FUNCTION” button

until the light under the selection you desire is lit up.

NOTE: In the COLD mode, the LED will read the actual temperature of the product (the
temperature setting is preset to NSF standards and is not adjustable.) In the “FROZEN” or “OFF”
mode the LED will read the current time.

Setting the 12 or 24 Hour Display and

o

F or

o

C Temperature Display

1.

Turn the power switch OFF.

2.

Press and hold the left “AUGER ON/OFF” button and turn ON the power switch. Release the

“AUGER ON/OFF” button when either “12” or “24” are shown (indicates the current hour view).

3.

Press the “PRESS TO SELECT FUNCTION” button until either

o

F or

o

C is shown on the display.

4.

Press the “AUTO TIMER” button until the desired temperature display type is shown (

o

F or

o

C).

5.

Store the change by pressing the “PRESS TO SELECT FUNCTION” button until the current time is

displayed. The unit is now ready for use.