Ice Frost Operator’s Manual

© 2004-2006, IMI Cornelius Inc.

- 25 -

Publication Number: M620919596OPR

TROUBLESHOOTING

NOTE: The following procedures must be performed by a qualified service technician.

Problem

Possible Cause

Solution

“Filt” or “Err” message appears on
the touchpad LED readout

• The filter is dirty and needs to

be cleaned

• The unit is positioned too close

to a wall or other object restrict-
ing air flow and causing the
machine to run at a higher tem-
perature

• The filter is not properly

installed

• The unit has been installed

near a heat source, such as a
coffee machine, ice maker or
cold beverage machine which
expels hot air from its vents,
causing the machine to run at a
high temperature. (Installation
near a heat source should be
avoid)

• Clean and replace filter follow-

ing instructions (Removing and
Cleaning Filter)

• Reposition unit to maximize

ventilation space (see installa-
tion figures)

• Properly install filter see

“Removing and cleaning filter”

• Reposition unit to maximize

ventilation space (see installa-
tion figures)

The machine does not cool, or
cools only partially, but the com-
pressors are running

• The space around the machine

is inadequate for ventilation

• Freezer is in COLD mode

• The condenser fins are clogged

with airborne particles

• Fan motor is not running

• Refrigerant is low

• Allow at least 8” (20cm)

between the machine and any-
thing next to it; keep away from
heat sources

• Return to FROZEN mode

• Remove the side panels. Using

a brush or compressed air
clean the condenser

• Check the fan motor’s electrical

connections and, if discon-
nected, reconnect. If still not
operating, replace the motor

• Locate the leak, eliminate it and

recharge the system

The machine does not cool or
cools only partially, but one or
more of the compressors are not
running

Defective Electrical components

Loose wire connections

One or more of the compressors
are malfunctioning

No current is coming to the
“compressor delay” PC board

Replace the malfunctioning compo-
nents

Check the contacts and correct
those that are incomplete

Replace the compressor(s)

Check the electrical connections to
the PC board as well as the trans-
former feeding the PC board and
correct