SPECIAL MAINTENANCE

ATTENTION: To guarantee peak cooling
system performance level, the routine cleaning
of the condenser filter is essential.

As explained earlier, an audible signal accompanied by
the word FILT appearing on the control panel display,
will warn the operator when the filter is clogged and so
must be cleaned before the machine comes to an
automatic stop.

• Disconnect the machine from the power supply;

• Unscrew the nut (C in FIGURE 27).

• Remove the cover (B in FIGURE 27).

• Disconnect the plug (D in FIGURE 28).

• Loosen and rotate the bracket.

• Lift and remove the back (E in FIGURE 28).

• Clean the filter behind the net, then clean the

condenser with a brush, if necessary.

WARNING: You are reminded that all the opera-
tions described above must be carried out with
the machine switched off and the power cable dis-
connected.

FIGURE 27

FIGURE 28

R

ESTRICTED

A

IR

F

LOW

A

LARM

To protect the entire cooling system, the Ice Frost
drinks maker is fitted with an electronic system which
issues an acoustic warning signal in the event of
insufficient ventilation or if the condenser filter is
clogged. In addition to this, the words FILT and then
ERR will appear on the control panel display.

FIGURE 29

If the operator does not intervene when the signal is
issued, restoring normal working conditions (i.e.
ensuring better ventilation or cleaning the filter), this
electronic system will stop the machine automatically.

FIGURE 30