Ice Frost Operator’s Manual

© 2004-2006, IMI Cornelius Inc.

- 27 -

Publication Number: M620919596OPR

Problem

Possible Cause

Solution

Cap is leaking

• The nut is loose

• Tighten the nut

Bowl not refilling

• Out of syrup

• Out of CO

2

• Valves are shut off or blocked

• Foam covering probes

• Fill Switch in off position

• Defective syrup pressure switch

• Defective CO

2

shut off

• Replace

• Replace

• Open

• Wait

• Turn on

• Replace

• Replace

Bowl is overfilling

• Bad Pressure and Levels Card

• Replace the card

CO

2

leaking from back of unit

• Proper function of bowl over

pressure discharge solenoids

• Poor connection

• If not continuous leak it is nor-

mal operation

• Repair leak

WARNING: Relief valve venting is normal, a continuous leak is not and must be corrected immedi-
ately. Repair the solenoid valve.