5. Operational Tests

Test the emergency stop button at the operator console and the Occupant Panic

Switch inside the cockpit.

Test the operation console controls (CPU menu driven) for proper operation. During

start-up check for any error indications or signs that the computer is not functioning

correctly.

Test the operation of the fire alarm interface (alarm should indicate E-stop mode, if

installed).

Test the raise and balance functions.

Test the door interlock switch (Canopy Open Sensor) for proper operation.

Test the house lighting for correct operation.

Test the manual quick release of the harness.

Check the harness release lever for proper operation.

Check the computer diagnostic functions.

6. Safety Systems and Devices

Check for proper operation of the emergency lighting and battery packs.

Check the condition, content and location of all warning and information signs.

Check for classical hazard guarding in the guest areas.

Check the fire extinguishers for condition and location.

Visually check the lap belt for damage and deterioration.

Visually check the secondary restraint harness for damage and deterioration.

Review the passenger restrictions for compliance to the manufacturer’s

recommendations.

Check the building fire alarm system for activation devices and audible alarms in the

ride area.

Check the evacuation routes for proper clearances and accessibility.

7. Queue and Holding Areas

Visually inspect the queue, walls and fencing for security and damage.

Visually inspect the holding areas and pre-show areas for hazards to guests.

Check for proper queuing techniques.

Check for adequate lighting in the guest traffic areas.