InFocus MaxFlight MT3000(B) User Manual

Page 83

Advertising
background image

4.)

Appearance, external cracks, discoloration, leakage. When measured capacitance

of he capacitor has reduced below 85% of the rating, change the capacitor.

Figure 2

Time Replacement Chart










6-2

Relays

To prevent a contact fault, etc., relays must be changed according to the number of accumulative switching
times (switching life is approximately 30,000 rides).

6-3 Projector Bulb

To prevent an excessive down time, due to the projector bulb burning out, obtain a spare bulb whenever the
INFOCUS run time states over 750 hours. We do not know at this time how long this bulb lasts. This is
only a suggestion for having on hand this spare part, not a requirement.

Note: Projector bulbs can be obtained from Infocus direct by ordering from a local distributor or going on
the internet to (

WWW.INFOCUS.COM

). Also the projector is warranted by Infocus direct by a pass

through warranty. Any maintenance done to the projector will void the warranty. Should you require a
loaner, Infocus will overnight delivery you a loaner for a fee if given a major credit card.

6-4 NONDESTRUCTIVE TEST LIQUID PENETRANT METHOD

• Remove all paint a minimum of one inch of the weld area.
• Clean area with solvent and allow to dry.
• Apply penetrant to test area allowing ample time to seep into openings.
• Remove penetrant remaining on surface without removing the penetrant from openings.
• Apply developer.
• Visually examine the weld for penetrant indications in the developer coating.
• Once again clean the tested area of developer and any traces of penetrant.


Part Name

Cooling Fan

Smoothing Capacitor Main Ckt.

Smoothing Capacitor Control Brd.

Standard Replacement Interval

2 to 3 Years

5 Years

5 Years

Description

Change as Required

Change as Required

Change the board as requd.

Change as Required

Relays

-------------------

Advertising