a. Squeeze the latch and pull the lever open 90° (so that the lever is

horizontal) to release the power supply and fan unit from the latch. The
latch is a coral colored tab on the lever.

b. Slowly pull the lever away from the chassis to remove the power supply

and fan unit, as shown in Figure 17 on page 39. (Remove the power
supply and fan unit from the chassis and place it on ESD protected
surface.)

Note: The lever rotates upward or downward 90°, depending on whether

the power supply and fan unit you are removing is in the right or left
power supply and fan unit bay.

c. Repeat steps 6a and 6b for the other power supply and fan unit.

7. Label the Enhanced Disk Drive Module (E-DDM) CRUs so you know their

physical location in the midplane.

8. Remove the E-DDM CRUs and any blank drive CRUs if the storage subsystem

has them. See “Removing an E-DDM” on page 39 for instructions. Place
E-DDMs on ESD protected surface.

Attention:

Do not stack E-DDM CRUs on top of each other. Protect the

E-DDM CRUs from vibrations or sudden shocks.

9. Use a #1 Phillips screwdriver to loosen the four front cage frame screws on

the midplane, as shown in Figure 86.

10. On the back of the DS5020, remove the four Phillips screws (two screws on

each side) that hold the sides of the DS5020 chassis to the sides of the rails.

11. On the front of the DS5020, remove the four M5 screws (two screws on each

side) on the DS5020 chassis that hold the DS5020 to the rails.

Attention:

The unit must be removed from the rack and placed on a level

ESD protected surface before servicing it.

12.

Statement 4:

810midpl

Front cage frame screws

Front cage frame screws

Figure 86. Front cage frame screw locations