background image

Table 20. Symptom-to-FRU index (continued)

Problem
indicator

Component

Possible cause

Possible solutions

Unable to access
drives

Drives and
Fibre Channel
loop

Incorrect storage
subsystem ID
settings

Make sure that the Fibre Channel
optical cables are undamaged
and properly connected. Check
the storage subsystem ID
settings.
Note: Change the switch
position only when your storage
subsystem is powered off.

RAID controller
failure

Replace one or both RAID
controllers. Contact an IBM
technical support representative.

Drive or drives
failed

Replace failed drive or drives.

Random errors

Storage
subsystem

Midplane failure

Have the midplane replaced.
Contact an IBM technical support
representative.

Hard disk drive is
not visible in RAID
management
software

Several CRUs

Drive or drives
failed

Replace failed drive or drives.

Fibre Channel cable
failed

Replace Fibre Channel cable.

SFP failed

Replace SFP.

RAID controller
failure

Replace RAID controller.

Midplane failure

Have the midplane replaced.
Contact an IBM technical support
representative.

Drive CRU has
interface problem
with the ESM or
controller.

Replace the drive CRU.

Incorrect firmware
version

Verify that the DS5020 storage
subsystem has the correct
firmware version. Refer to
“Software and hardware
compatibility and upgrades” on
page 17.

A controller has
failed in addition to
the ESM failure in
the drive channel
that originates from
the functioning
controller.

Replace the failed controller and
ESM.

Chapter 6. Hardware maintenance