Table 20. Symptom-to-FRU index (continued)

Problem
indicator

Component

Possible cause

Possible solutions

One or more
green LEDs are
off

Power supply
CRUs

Power cable is
unplugged or
switches are turned
off.

Make sure that the power cable
is plugged in and that the
switches are turned on.

All drive CRUs

Midplane failure

Replace the midplane. Contact
an IBM technical support
representative.

Several CRUs

Hardware failure

Replace the affected CRUs. If
this does not correct the problem,
replace the RAID controllers,
followed by the midplane.
Contact an IBM technical support
representative.

Front panel

Power supply
problem

Make sure that the power cables
are plugged in and that the
power supplies are turned on.

Hardware failure

If any other LEDs are lit, replace
the midplane. Contact an IBM
technical support representative.