Cornelius SID650A/80 User Manual

Page 22

Advertising
background image

19

91704

1. TOTALLY INOPERATIVE

POWER

PRESENT AT

REAR JUNCTION

BOX?

NO

NO

NO

NO

YES

YES

YES

YES

IS

SUPPLY FUSE

BLOWN (OR C/B

TRIPPED)?

CHECK FOR LOOSE CONNECTION

OR BROKEN WIRE INSIDE UNIT.

IS LINE

VOLTAGE

WITHIN 10% OF

NAMEPLATE

VOLTAGE?

CHECK FOR LOOSE CONNECTION

OR BROKEN WIRE IN SUPPLY

WIRING OF UNIT.

IS

FUSE OR C/B

SIZE PROPER?

REPLACE WITH CORRECT

SIZE DEVICE.

IS

LINE VOLTAGE

HIGH OR

LOW?

INSTALL BUCKING TRANSFORMER

TO REDUCE LINE VOLTAGE.

IS

OTHER EQUIP.

ON SAME

CIRCUIT?

LOW

HIGH

YES

NO

1. CHECK FOR SHORT CIRCUIT IN

WIRING INSIDE UNIT.

2. CHECK COMPONENTS FOR SHORT

CIRCUIT OR GROUNDED WIRING.

1. REMOVE ALL OTHER EQUIPMENT

FROM ICE MAKER CIRCUIT.

2. INSTALL NEW DEDICATED CIRCUIT

FOR ICE MAKER.

1. CHECK FOR LOOSE OR CORRODED CON-

NECTION IN SUPPLY WIRING.

2. CHECK SUPPLY WIRING FOR UNDER-

SIZED WIRE, AND REPLACE.

3. INSTALL BOOSTING TRANSFORMER TO

RAISE LINE VOLTAGE.