IMPORTANT: To ensure proper ice maker operation and also to reduce the frequency of water-related

service problems, a water filter should be installed. Remcor recommends the use of IMI Cornelius filter,

model number 81COR01PS.

For specific recommendations on these filter systems for your local conditions, consult with a distributor in your

area or contact the filter manufacturer.

Connect two (2) 3/4 IPS (or equal) drain lines to the 3/4 threaded drain connections at the lower rear of the

unit. These lines must pitch downward to an open drain and must contain no traps or improper drainage

will result.

NOTE: In areas where consistently warm water temperatures are encountered, the use of a Remcor Pre-

Cooler in the water line is recommended to maximize the ice production of this unit. Contact Remcor

for more information on this product.

3. Electrical

A 4 x 2 junction box is located at the rear of the unit for the supply hook-up. Connect the ice maker to its

own individual circuit per the national electric code and local code. See SPECIFICATIONS for ampacity

and fuse size.

IMPORTANT: The wire size must be adequate for the ampacity rating, and the supply voltage must be

within a range of ± 10% for proper ice maker operation.

NOTE: The units require a 2 wire system plus earth ground for proper operations.

220V

1 PHASE

60 HERTZ

SUPPLY CONDUIT

BROWN (HOT)

BLUE (NEUTRAL)

GREEN (GROUND)

REAR VIEW -- BOTTOM SECTION SERVICE PANEL REMOVED

FIGURE 1. ELECTRICAL WIRING INSTALLATION INSTRUCTIONS