23

91704

YES

NO

2.C NO ICE ON EVAPORATOR

IS

HARVEST

TIMER

RUNNING?

IS

EVAPORATOR

COLD?

IS

WATER LEVEL

NORMAL?

IS

HOT GAS SOLENOID

ENERGIZED?

CHECK

REFRIGERATION

SYSTEM.

CHECK WATER

PROBLEMS IN 2.A

IS

COND. CONTROL

ENERGIZED?

CHECK TIMER

SWITCH #1.

IS

HARVEST TIMER

HOME?

NO

YES

YES

NO

NO

YES

YES

NO

YES

NO

1. CHECK FOR REFRIGERANT

UNDER-CHARGE.

2. CHECK HOT GAS SOLENOID

FOR LEAKING SEAT.

3. GO TO 2.A.

1. CHECK FOR OPEN CONDUCT

PROBE WIRING.

2. CHECK CONDUCTIVITY

CONTROL.

1. CHECK ADJUSTMENT OF

TIMER CAM #2. (HOT GAS)

2. CHECK TIMER SWITCH #2.

1. CHECK ADJUSTMENT OF TIMER

CAM #1. (TIMER HOME)

2. CHECK TIMER SWITCH #1.
3. CHECK TIMER MOTOR.