2.D FROZEN EVAPORATOR

IS

AMBIENT ABOVE

60 F?

IS

VOLTAGE WITHIN

10%?

CHECK VOLTAGE ITEMS IN 1.

DISCONNECT PROBE WIRE FROM

CONDUCTIVITY CONTROL.

DOES

TIMER

START?

HOT

GAS OPERATION

O.K.?

WATER

DUMP

O.K.?

HARVEST

MOTOR OPERATION

NORMAL?

YES

NO

NO

YES

YES

YES

YES

NO

NO

NO

1. SHUTOFF ICE MAKER AND THAW EVAPORATOR.
2. START ICE MAKER.

1. ARRANGE TO MAINTAIN MINIMUM

60 F AMBIENT.

2. CONDUCT FACTORY REGARDING

SPECIAL APPLICATION.

1. CHECK TIMER MOTOR.
2. CHECK CONDUCTIVITY CONTROL.

1. CHECK ADJUSTMENT OF TIMER

CAM #2. (HOT GAS)

2. CHECK TIMER SWITCH #2.
3. CHECK HOT GAS SOLENOID.

1. CHECK ADJUSTMENT OF TIMER

CAM #4. (WATER DUMP)

2. CHECK TIMER SWITCH #4.
3. CHECK DUMP SOLENOID.