Cornelius SID650A/80 User Manual

Page 31

Advertising
background image

28

91704

YES

3. DISPENSER PROBLEM

NO

DOES

AGITATOR

ROTATE?

1. CHECK MOTOR CAPACITOR.
2. CHECK TIMER SWITCH #5.
3. CHECK AGITATOR MOTOR.

IS

VOLTAGE AT

SOLENOID

103-126V.?

1. CHECK FOR BURNED OUT SOLENOID.
2. CHECK FOR STUCK OR BINDING GATE

MECHANISM.

IS

HOPPER LEVEL

TOO HIGH?

1. CHECK FOR BLOWN SOLENOID FUSE IN ELEC-

TRICAL BOX. IF FUSE IS BLOWN, CHECK FOR

STUCK GATE MECHANISM, BURNED OUT SOLE-

NOID, OR LOW VOLTAGE.

2. CHECK VEND SWITCH.
3. CHECK FOR LOOSE OR BROKEN WIRE CONNEC-

TION IN SOLENOID CIRCUIT.

4. CHECK VOLTAGE PROBLEMS IN 1.

1. CHECK BIN THERMOSTAT

ADJUSTMENT.

2. REPLACE BIN THERMOSTAT.

IS

ICE SLUSHY?

DONE

1. CHECK HOPPER DRAINS.
2. CHECK LEVEL OF UNIT.
3. CHECK FOR WATER OVERFLOW FROM EVAP-

ORATOR. SEE SECTION 2.

4. CHECK ADJUSTMENT OF TIMER CAM #5.

(AGITATION)

5. CHECK TIMER SWITCH #5.

YES

YES

YES

YES

NO

NO

NO

NO

DOES

GATE OPEN?

Advertising
This manual is related to the following products: