Clustering support, Inventory checklist, Clustering – IBM Partner Pavilion DS4100 User Manual

Page 37: Support, Inventory, Checklist

Advertising
background image

Clustering

support

Clustering

is

a

means

of

sharing

array

groups

among

controllers

to

provide

redundancy

of

controllers

and

servers.

This

redundancy

is

important

if

a

hardware

component

fails.

If

a

hardware

component

failure

occurs

in

a

cluster,

another

server

takes

ownership

of

the

array

group.

Clustering

requires

software

specific

to

your

operating

system.

For

more

information

about

clustering,

go

to

the

following

Web

site:

www.pc.ibm.com/us/compat/nos/matrix.shtml

Inventory

checklist

After

you

unpack

the

DS4100

storage

server,

verify

that

you

have

the

following

items:

v

Hardware

Up

to

14

hard

disk

drives

(shipped

installed

in

the

DS4100)

Note:

The

DS4100

base

storage

server

is

shipped

with

no

SATA

hard

disk

drives

as

standard.

You

can

order

the

unit

with

up

to

14

250

GB

SATA

drive

CRUs

installed

at

the

factory.

The

DS4100

single-controller

storage

server

is

shipped

with

three

250

GB

SATA

drive

CRUs

as

standard.

You

can

order

the

unit

with

up

to

11

additional

SATA

drive

CRUs

installed

at

the

factory.

RAID

controllers

(shipped

installed

in

the

DS4100)

-

2

controllers

on

the

base

storage

server

-

1

controller

on

the

single-controller

storage

server

Note:

A

blank

controller

tray

is

installed

in

the

empty

controller

slot

in

the

DS4100

single-controller

storage

server

chassis.

For

proper

cooling

and

EMI

shielding,

do

not

remove

this

blank

controller

tray.

Two

fan

units

(shipped

installed

in

the

DS4100)

Power

supplies

(shipped

installed

in

the

DS4100)

-

2

power

supplies

on

the

base

storage

server

-

1

power

supply

on

the

single-controller

storage

server

Note:

A

blank

power

supply

tray

is

installed

in

the

empty

power

supply

slot

in

the

DS4100

single-controller

storage

server

chassis.

For

proper

cooling

and

EMI

shielding,

do

not

remove

this

blank

power

supply

tray.

Line

cord

jumpers

-

2

line

cord

jumpers

on

the

base

storage

server

-

1

line

cord

jumper

on

the

single-controller

storage

server

Line

cord

jumpers

are

power

cords

used

to

connect

the

DS4100

power

supply

units

to

the

IBM-certified

rack

power

distribution

units

(PDUs).

One

rack-mounting

hardware

kit,

including:

-

Two

rails

(right

and

left

assembly)

-

Eight

M6

black

hex-head

slotted

screws

-

Eight

M6

cage

nuts

-

Eight

M6

clip

nuts

Up

to

14

blank

drive

trays

(shipped

installed

in

the

DS4100)

Chapter

1.

Introduction

5

Advertising