Interface, Ports, Switches – IBM Partner Pavilion DS4100 User Manual

Page 44: Ds4100, Single-controller, Storage, Server, Figure

Advertising
background image

RAID

controller

Each

RAID

controller

contains

several

connectors

and

LEDs.

Each

controller

has

two

host

ports

and

one

expansion

port

for

connecting

the

storage

server

to

hosts

or

expansion

units.

You

first

insert

SFPs

into

the

ports

and

then

connect

the

fibre

channel

cables.

Host

ports

The

host

ports

(labelled

Host

1

and

Host

2)

are

used

to

connect

a

fibre

channel

cable

from

the

host

systems.

You

first

insert

an

SFP

into

the

port

and

then

connect

a

fibre

channel

cable.

The

two

host

ports

in

each

controller

are

independent.

They

are

not

connected

in

the

controller

module

as

they

would

be

in

a

hub

configuration.

The

host

port

connections

can

auto-negotiate

between

1

Gbps

and

2

Gbps.

Ethernet

port

The

Ethernet

port

is

used

for

an

RJ-45

10BASE-T

or

100BASE-T

Ethernet

connection

to

each

controller.

Use

the

Ethernet

connection

to

directly

manage

the

DS4100.

Expansion

port

The

expansion

port

(labelled

Expansion)

is

used

to

connect

additional

expansion

units

to

the

RAID

controllers

on

the

DS4100

base

storage

server.

You

first

insert

an

SFP

into

the

port

and

then

connect

a

fibre

channel

cable.

Note:

In

the

DS4100

single-controller

storage

server,

the

expansion

port

on

the

RAID

controller

is

not

active.

Serial

port

The

serial

port

is

used

by

service

personnel

to

perform

diagnostic

operations

on

the

RAID

controllers.

Incorrect

use

of

the

serial

port

can

result

in

loss

of

data

access

and,

in

some

cases,

in

loss

of

data.

Note:

The

maximum

baud

rate

is

57

600

bps.

Server

ID

switch

(enclosure

ID

switch)

The

server

ID

(also

referred

to

as

enclosure

ID)

switch

settings

range

from

0

through

7.

When

connecting

the

DS4100

base

storage

server

to

DS4000

EXP100

storage

expansion

units,

only

the

unique

IDs

ranging

from

00

through

07

can

be

set.

Host port 1

Host port 2

Ethernet

Expansion port (inactive in the DS4100

single-controller storage server)

AC power
connector

AC power

switch

Serial port

Server ID

switch

1 Gbps/
2 Gbps
switch

f10ug022scu

Figure

7.

Interface

ports

and

switches

for

DS4100

single-controller

storage

server

12

IBM

TotalStorage

DS4100

Storage

Server:

Installation,

User’s,

and

Maintenance

Guide

Advertising