Ds4100 specifications, Ds4100, Specifications – IBM Partner Pavilion DS4100 User Manual

Page 46: Totalstorage, Table

Advertising
background image

DS4100

specifications

Table

9

lists

the

physical

specifications

for

the

DS4100.

Table

9.

IBM

TotalStorage

DS4100

specifications

Size

v

Width:

48.18

cm

(18.97

in.)

v

Height:

13.23

cm

(5.21

in.)

v

Depth:

59.74

cm

(23.52

in.)

Weight

v

Drive-ready

weight

(without

disk

drive

modules

installed):

Model

100:

26.64

kg

(58.9

lb)

Model

1Sx:

23.44

kg

(51.9

lb)

v

Fully

configured

weight

(with

14

disk

drives

installed):

Model

100:

40.36

kg

(89

lb)

Model

1Sx:

37.16

kg

(82

lb)

Environment

v

Air

temperature

Operating:

-

Altitude:

0

-

914

m

(3000

ft):

10°

-

35°

C

(50°

-

95°

F)

-

Altitude:

914

m

-

2133

m

(3000

-

7000

ft):

10°

-

32°

C

(50°

-

90°

F)

Important:

The

recommended

operating

environment

air

temperature

is

22°

C

(72°

F)

or

lower.

Storage:

-

Altitude:

0

-

914

m

(3000

ft):

-

60°

C

(33°

-

140°

F)

-

Altitude:

914

m

-

2133

m

(3000

-

7000

ft):

-

57°

C

(33°

-

135°

F)

v

Humidity

8%

-

80%

Noncondensing

Heat

dissipation

v

Fully

configured

storage

server

(14

1.5

Gbps

SATA

hard

disk

drives)

1235

BTU

per

hour

Acoustical

noise

emission

values

For

open

bay

(0

drives

installed)

and

typical

system

configurations

(eight

hard

disk

drives

installed):

v

Sound

power

(idling):

5.9

bel

(open

bay)

6.1

bel

(typical)

v

Sound

power

(operating):

5.9

bel

(open

bay)

6.2

bel

(typical)

v

Sound

pressure

(idling):

44

dBA

(open

bay)

46

dBA

(typical)

v

Sound

pressure

(operating):

44

dBA

(open

bay)

47

dBA

(typical)

These

levels

are

measured

in

controlled

acoustical

environments

according

to

ISO

7779

and

are

reported

in

accordance

with

ISO

9296.

The

declared

sound

power

levels

indicate

an

upper

limit,

below

which

a

large

portion

of

machines

operate.

Sound

pressure

levels

in

your

location

might

exceed

the

average

1-meter

values

stated

because

of

room

reflections

and

other

nearby

noise.

Notes:

1.

The

nonoperating

environment

must

not

exceed

the

operating

environment

limits

for

longer

than

60

days.

2.

The

storage

environment

must

not

exceed

the

operating

environment

limits

for

longer

than

1

year.

3.

Substantial

deviations

from

the

suggested

operating

range,

in

either

direction,

if

sustained

for

extended

periods

of

time,

will

expose

the

unit

to

greater

risk

of

failure

from

external

causes.

The

AC

power

sources

must

provide

the

correct

voltage,

current,

and

frequency

specified

on

the

storage

server.

The

storage

server

can

run

without

interruption

within

the

limits

shown

in

Table

10

on

page

15.

14

IBM

TotalStorage

DS4100

Storage

Server:

Installation,

User’s,

and

Maintenance

Guide

Advertising