IBM 6341 User Manual

Page 105

Advertising
background image

POST Error Code

FRU/Action

6XX
Not listed above

1.

Diskette Drive

2.

System Board

3.

Riser card

4.

External Drive Adapter

5.

Diskette Drive Cable

6.

Power Supply

762
Math coprocessor configuration error

1.

Run Setup

2.

Processor

3.

System Board

7XX
Not listed above

1.

Processor

2.

System Board

962
Parallel port configuration error

1.

Run Configuration

2.

Parallel Adapter (if installed)

3.

System Board

9XX

1.

Printer

2.

System Board

1047

1.

16-Bit AT

Fast SCSI Adapter

107X
Check SCSI terminator installation

1.

Check SCSI terminator installation

2.

SCSI Cable

3.

SCSI Terminator

4.

SCSI Device

5.

SCSI Adapter

1101
Serial connector error, possible system board
failure

1.

Run Enhanced Diagnostics

1101, 1102, 1106, 1108, 1109

1.

System Board

2.

Any Serial Device

1107

1.

Communications Cable

2.

System Board

1102
Card selected feedback error

1.

Run Enhanced Diagnostics

1103
Port fails register check

1.

Run Enhanced Diagnostics

2.

System Board

1106
Serial option cannot be turned off

1.

Run Enhanced Diagnostics

2.

System Board

1107

1.

Serial Device Cable

2.

System Board

1110
Register test failed

1.

Run Enhanced Diagnostics

2.

System Board

1116
Interrupt error

1.

Run Enhanced Diagnostics

Chapter 6. Symptom-to-FRU Index