IBM 6341 User Manual

Page 89

Advertising
background image

Diagnostic Error Code

FRU/Action

018-195-XXX
PCI Card Test aborted by user

1.

PCI card

2.

Information

3.

Re-start the test, if necessary

018-196-XXX
PCI Card test halt, error threshold exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

018-197-XXX
PCI Card test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

018-198-XXX
PCI Card test aborted

1.

Make sure the component that is called
out is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

018-199-XXX
PCI Card test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

018-250-XXX
PCI Card Services error

1.

PCI card

2.

Riser card, if installed

3.

System board

020-000-XXX
PCI Interface Test Passed

1.

No action

020-0XX-XXX
PCI Interface error

1.

PCI card

2.

Riser card, if installed

3.

System board

020-195-XXX
PCI Test aborted by user

1.

Information

2.

Re-start the test, if necessary

020-196-XXX
PCI test halt, error threshold exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

020-197-XXX
PCI test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

020-198-XXX
PCI test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

Chapter 6. Symptom-to-FRU Index

81

Advertising