Diagnostic Error Code

FRU/Action

020-199-XXX
PCI test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

020-262-XXX
PCI system error

1.

PCI card

2.

Riser card, if installed

3.

System board

025-000-XXX
IDE interface Test Passed

1.

No action

025-00X-XXX
025-01X-XXX
IDE interface failure

1.

IDE signal cable

2.

Check power supply

3.

IDE device

4.

System board

025-027-XXX
IDE interface Configuration/Setup error

1.

IDE signal cable

2.

Flash the system

3.

IDE device

4.

System board

025-02X-XXX
025-03X-XXX
025-04X-XXX
IDE Interface failure

1.

IDE signal cable

2.

Check power supply

3.

IDE device

4.

System board

025-195-XXX
IDE interface Test aborted by user

1.

Information

2.

Re-start the test, if necessary

025-196-XXX
IDE interface test halt, error threshold
exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

025-197-XXX
IDE interface test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

025-198-XXX
IDE interface test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

025-199-XXX
IDE interface test failed, cause unknown

1.

Go to the

″Undetermined problems″

section

2.

Flash the system and re-test

3.

Replace component under function test

030-000-XXX
SCSI interface Test Passed

1.

No action

82

Hardware Maintenance Manual