IBM 6341 User Manual

Page 91

Advertising
background image

Diagnostic Error Code

FRU/Action

030-00X-XXX
030-01X-XXX
SCSI interface failure

1.

SCSI signal cable

2.

Check power supply

3.

SCSI device

4.

SCSI adapter card, if installed

5.

System board

030-027-XXX
SCSI interface Configuration/Setup error

1.

SCSI signal cable

2.

Flash the system

3.

SCSI device

4.

SCSI adapter card, if installed

5.

System board

030-03X-XXX
030-04X-XXX
SCSI interface error

1.

SCSI signal cable

2.

Check power supply

3.

SCSI device

4.

SCSI adapter card, if installed

5.

installed System board

030-195-XXX
SCSI interface Test aborted by user

1.

Information

2.

Re-start the test, if necessary

030-196-XXX
SCSI interface test halt, error threshold
exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

030-197-XXX
SCSI interface test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

030-198-XXX
SCSI interface test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

030-199-XXX
SCSI interface test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

035-000-XXX
RAID interface Test Passed

1.

No action

035-0XX-XXX
RAID interface Failure

1.

RAID signal cable

2.

RAID device

3.

RAID adapter card, if installed

4.

System board

035-195-XXX
RAID interface Test aborted by user

1.

Information

2.

Re-start the test, if necessary

Chapter 6. Symptom-to-FRU Index

83

Advertising
This manual is related to the following products: