Diagnostic Error Code

FRU/Action

000-197-XXX
BIOS test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

000-198-XXX
BIOS test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

000-199-XXX
BIOS test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

000-250-XXX
BIOS APM failure

1.

Flash the system

2.

System board

000-270-XXX
BIOS ACPI failure

1.

Flash the system

2.

System board

001-000-XXX
System Test Passed

1.

No action

001-00X-XXX
System Error

1.

System board

001-01X-XXX
System Error

1.

System board

001-024-XXX
System Addressing test failure

1.

System board

001-025-XXX
System Checksum Value error

1.

Flash the system

2.

System board

001-026-XXX
System FLASH data error

1.

Flash the system

2.

System board

001-027-XXX
System Configuration/Setup error

1.

Run Setup

2.

Flash the system

3.

System board

001-032-XXX
System Device Controller failure

1.

System board

001-034-XXX
System Device Buffer Allocation failure

1.

Reboot the system

2.

Flash the system

3.

Run memory test

4.

System board

001-035-XXX
System Device Reset condition detected

1.

System board

001-036-XXX
System Register error

1.

System board

Chapter 6. Symptom-to-FRU Index