IBM 6341 User Manual

Page 87

Advertising
background image

Diagnostic Error Code

FRU/Action

014-001-XXX
Parallel port Presence

1.

Remove external parallel device, if
present

2.

Run setup, enable port

3.

System board

014-002-XXX
014-003-XXX
Parallel port Timeout/Parity error

1.

System board

014-013-XXX
014-014-XXX
Parallel port Control Signal/Loopback test
failure

1.

System board

014-015-XXX
Parallel port External Loopback failure

1.

Wrap plug

2.

System board

014-027-XXX
Parallel port Configuration/Setup error

1.

Run Setup, enable port

2.

Flash the system

3.

System board

014-03X-XXX
014-04X-XXX
Parallel port failure

1.

System board

014-195-XXX
Parallel port Test aborted by user

1.

Information

2.

Re-start the test, if necessary

014-196-XXX
Parallel port test halt, error threshold
exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

014-197-XXX
Parallel port test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

014-198-XXX
Parallel port test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

014-199-XXX
Parallel port test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

014-2XX-XXX
014-3XX-XXX
Parallel port failure

1.

External parallel device

2.

System board

015-000-XXX