IBM 6341 User Manual

Page 97

Advertising
background image

Diagnostic Error Code

FRU/Action

217-28X-XXX
217-29X-XXX
Hard Disk Drive (SCSI) error

1.

Hard Disk Drive Cable

2.

Check power supply voltages

3.

Hard Disk drive (SCSI)

4.

SCSI adapter card

5.

System board

220-000-XXX
Hi-Capacity Cartridge Drive Test Passed

1.

No action

220-XXX-XXX
Hi-Capacity Cartridge Drive error

1.

Remove the Hi-Capacity Cartridge
Drive and re-test the system

301-XXX-XXX
Keyboard error

1.

Keyboard

2.

Check and test mouse

3.

System board

301-000-XXX
Keyboard Test Passed

1.

No action

302-000-XXX
Mouse Test Passed

1.

No action

302-XXX-XXX
Mouse error

1.

Mouse

2.

Check and test Keyboard

3.

System board

303-000-XXX
Joystick Test Passed

1.

No action

303-XXX-XXX
Joystick error

1.

Remove the Joystick and re-test the
system

305-000-XXX
Monitor DDC Test Passed

1.

No action

305-250-XXX
Monitor DDC self test failure

1.

Run Setup to enable DDC

2.

Cable

3.

Monitor

4.

Video card

5.

System board

415-000-XXX
Modem Test Passed

1.

No action

415-XXX-XXX
Modem error

1.

Remove the Modem and re-test the
system

Chapter 6. Symptom-to-FRU Index