Port error statistics, Description – Intel NetStructure 470 User Manual

Page 112

Advertising
background image

106

C

H

A

P

T

E

R

5

Intel® NetStructure™ 470T and 470F Switches User Guide

Port Error Statistics

Description

Select port: Selects the range of ports to view. You can view statistics for
four ports at a time. Press

z to toggle between port numbers. The

example shows ports 1–4.

Update interval: Selects the time period between updates (press

z).

For example, an update interval of 5 sec. means Local Management collects
and displays information from the switch every five seconds.

Speed/Duplex: Displays the current connection status of the port.

CRC error: Displays the number of valid-length frames (between 64 and
1536 bytes) that had a bad frame check sequence (FCS).

Oversize frames: Displays the number of frames that exceed the maximum
allowed frame size but are otherwise valid Ethernet frames (good CRC).

Fragments: Displays the number of frames that are less than 64 bytes,
including frames without a start-of-frame delimiter. A fragmented frame
also has an invalid CRC.

Jabber: Indicates that a device (such as a faulty NIC) on the network is
sending improper electrical signals. Because Ethernet uses electrical
signaling to determine whether it can transmit, a jabber condition can halt
all traffic on a segment.

LOCATION

Main Menu

Monitoring

Port Error Statistics

Advertising