Troubleshooting – Icom IC-R1500 User Manual

Page 54

Advertising
background image

49

TROUBLESHOOTING

11

PROBLEM

POSSIBLE CAUSE

SOLUTION

REF.

If your receiver seems to be malfunctioning, please check the following points before sending it to a service center.

Does not turn on.

No sound comes from the
speaker.

Sensitivity is low and only
strong signals are audible.

Frequency cannot be set.

Program scan does not
operate.

Memory scan does not op-
erate.

Receive audio is distorted.

• An AC adapter is not connected to the receiver.

• Volume level is too low.
• Squelch level is set too high.
• Different tone is selected with tone or DTCS

squelch.

• Antenna feedline or the antenna connector has a

poor contact or is short circuited.

• Attenuator function is activated.

• The lock function is activated.

• The squelch is open.
• The start and end frequencies are the same.

• The squelch is open.
• Only 1 memory channel is programmed or other

channels are set as skip channel.

• The operating mode is not selected correctly.

• Check the connection.

• Rotate [VOL] to obtain a suitable level.
• Rotate [SQL] to set the squelch level.
• Turn the appropriate function OFF.

• Check, and if necessary, replace the feedline or sol-

der the antenna connector again.

• Push [ATT•PRIO] to turn the Attenuator function

OFF.

• Push and hold [SET•LOCK] for 1 sec. to turn the

function OFF.

• Set the squelch to the threshold point.
• Set the different frequencies.

• Set the squelch to the threshold point.
• Program other memory channels or cancel the

memory skip function in the desired channels.

• Push and hold [TS•MODE] for 1 sec., then rotate

[DIAL] to select suitable operating mode.

p. 1

p. 11
p. 11
p. 33

p. 1

p. 12

p. 11

p. 11
p. 27

p. 11
pgs. 17,

28

p. 10

Advertising