13

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Wall Shield Installation

The decorative Wall Shield, included in the Miscellaneous
Hardware bag, is used to obscure the vent hole in the
wall in installations vented directly off the rear of the
stove. Follow this procedure:
1. Remove the top two 1/4” hex head screws from the

rear shroud of the stove.

2. Align the holes in the wall shield with the holes in the

rear shroud.

3. Secure the wall shield to the stove with the two 1/4”

hex head screws. See fig. 16.

Figure 15. Termination Clearance to overhangs

Figure 15.
Wall Shield installation.

76 mm

12 ”

305

mm

2 1/2”

64 mm

Figure 13. Horizontal Termination with Vertical Rise.

Wall Thimble

and Trim Collar

Max. 4 ft.

Horizontal

Run

Max. Two

90° Elbows

or One 90°

and Two

45° Elbows

Max. 15 ft.

Vertical Vent

Run