Gas supply connection – Jotul GF 100 DV II User Manual

Page 17

Advertising
background image

17

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Gas Supply Connection

NOTE: If the optional Blower will be installed, use a 90°
Elbow off the valve to create adequate clearance for the
main gas line.
The gas supply line connection is made to the valve just
inside the left rear leg. The gas supply line should be 3/8"
npt with a 1/2" diameter supply, or the appropriate size
to provide sufficient gas pressure to the valve regardless
of the input setting.

The use of a Flexible Gas Appliance Connector is

acceptable in many areas in the U.S. However, Canadian
methods vary depending on local code.

ALL INSTALLATIONS MUST COMPLY WITH LOCAL

CODE OR IN THE ABSENCE OF LOCAL CODE, MUST
COMPLY WITH THE MOST RECENT EDITION OF THE
NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR
CAN-B149.

All codes require a gas shut-off valve (gas cock) and

union, to be installed in the supply line, and in the same
room as the appliance. This allows for the disconnection
of the stove for servicing and maintenance. See fig. 23.

Figure 23.
Supply
valve
coupling.

Leak test:
1. Mix a 50-50 solution of water and dish soap.
2. Light appliance- see lighting instructions on the inside

back cover of this manual or on the stove’s rating plate.

3. Brush or spray all joints and connections with the soapy

water solution.

4. If bubbles appear at any connection or seam or a gas

odor is detected, immediately turn gas control knob to
the OFF position.

5. Tighten or reconnect the leaking joint and retest for any

gas leaks.

Orifice

Pilot Base

Pilot Head

Figure 20.
Pilot orifice removal and replacement.

A T-HANDLE GAS COCK IS REQUIRED IN

MASSACHUSETTS TO COMPLY WITH CODE

248CMR.

Secure all joints tightly using appropriate tools and

sealing compounds. For propane units be sure to use
compounds that are propane resistant. Turn on gas
supply and test for gas leaks using a soapy water solution.
Never use an open flame to check for leaks.

Figure 22.
Burner plate engagement.

Burner

Notch

Pin

Figure 21. Regulator Assembly.

Retainer

Clip

Regulator

Tower

Gasket

Apply

small

label

Mounting

Screws

Advertising
This manual is related to the following products: