1. PURGING THE GAS LINE: When lighting the appli-

ance for the first time, it will take a few moments to
clear the gas line of air. Once this purge is complete,
the appliance will operate as described in the
lighting instructions. See the inside back cover of
this manual or the stove Rating Plate attached the
bottom of the stove. Subsequent burner starts will
not require purging the gas line unless the supply
line is shut off.

2. PILOT FLAME: You can monitor the pilot flame

through the opening at the upper left corner burner
skirt, under the rear log. See fig. 29. The pilot flame
should be steady - not lifting or floating. The flame
should be blue in color around the pilot hood, with
traces of yellow toward the outer edges.
The pilot flame should engulf the top 3/8” of the
thermopile (to generate millivolt current) and the
top 1/8” of the thermocouple. The pilot flame
should project out of the pilot hood 1” at all three
ports. See figs. 30.

3. BURNER ADJUSTMENT: This stove is equipped with a

variable gas control valve that allows easy adjust-
ment of the flame height appearance and heat
output. To adjust the flame, rotate the HI/LOW knob,
located in the center of the valve face.
NO SMOKE OR SOOT SHOULD BE PRESENT. CHECK
LOG PLACEMENT IF ANY SOOT OR SMOKE IS
PRESENT. IF SOOT OR SMOKE PERSISTS, THE AIR
SHUTTER MAY NEED TO BE ADJUSTED.
See Air Shutter/Flame Appearance section of this
manual for proper air shutter settings and adjust-
ments. Note: the more offsets there are in the vent
system, the greater the need for an air shutter
adjustment. See page 30.

Figure 31. Flame appearance on the “high” setting after
approximately 15 to 20 minutes burning.

WARNING:

AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE

PERFORMED BY A QUALIFIED PROFESSIONAL

SERVICE TECHNICIAN.

CAUTION:

DO NOT ATTEMPT TO ALTER THE FLAME

APPEARANCE BY POSITIONING THE GAS

VALVE IN ANY OTHER POSITION OTHER

THAN THE FULL “ON” POSITION.

(25mm)

3/8”

(8mm)

Min.

1/8”

(3mm)

Min.

Figure 30. Proper pilot flame appearance.