Stove and vent clearance requirements, Alcove installation – Jotul GF 100 DV II User Manual

Page 8

Advertising
background image

8

GF 100 DV II Nordic QT
GF 200 DV II Lillehammer

Stove and Vent Clearance

Requirements

Minimum Clearances from the Stove to Combustibles:
Measured from the stove top plate. See figs. 2-4.

For Both Stoves

Rear:

0” (0 mm)

Ceiling:

42” (1066 mm)

Corner:

2” (50 mm)

Sides:

3” (76 mm)

Minimum Clearances between Vent Pipe and
Combustible Materials:
Horizontal Run:
Off the top of the pipe

2” (50 mm)

Off the sides and bottom

1” (25 mm)

Vertical Run:
All sides

1” (25 mm)

Figure 3. Mantel Clearances - stove flush with fireplace face.

Figure 4. Mantel Clearances - stove set back into fireplace,

6 1/2” maximum.

Figure 2. Alcove Installation Clearances.

CLEARANCE TO REAR WALL = ZERO (0”)

GF 100 DV

or

GF 200 DV

Max. Depth

24”

(610mm)

Alcove Installation

Maximum Alcove Depth:

24” (610 mm)

Minimum Alcove Width:

34” (864 mm)

Minimum Ceiling Height
from stove top:

42” (1066 mm)

Min. 34”

(864 mm)

Plinth Kit: 23 3/4 in. (603 mm)
Long Legs: 27 in. (686 mm)

GF 100 DV II

GF 200 DV II

Nordic QT

Lillehammer

A

49 in. (1245 mm)

51 1/2 in. (1308 mm)

B

47 1/2 in. (1206 mm)

50 in. (1270 mm)

C

46 in. (1168 mm)

48 1/2 in. (1232 mm)

D

44 1/2 in. (1130 mm)

47 in. (1194 mm)

E

43 in. (1092 mm)

45 1/2 in. (1156 mm)

F

17 3/4 in. (451 mm)

17 3/4 in. (451 mm)

G

22 1/4 in. (565 mm)

24 3/4 in. (629 mm)

Plinth Kit: 23 3/4 in. (603 mm)
Long Legs: 27 in. (686 mm)

GF 100 DV II

GF 200 DV II

Nordic QT

Lillehammer

A

50 in. (1270 mm)

52 1/2 in. (1333 mm)

B

48 1/2 in. (1232 mm)

51 in. (1295 mm)

C

47 in. (1194 mm)

49 1/2 in. (1257 mm)

D

45 1/2 in. (1156 mm)

48 in. (1219 mm)

E

44 in. (1118 mm)

46 1/2 in. (1181 mm)

F

4 1/4 in. (108 mm)

4 1/4 in. (108 mm)

G

22 1/4 in. (565 mm)

24 3/4 in. (629 mm)

11.5”

9.5”

7.5”

5.5”

Max. Mantel

Depth

Min. Mantel

Depth

Max. Top Trim

Depth = 1”

3.5

A

C

E

B

D

F

G

11.5”

9.5”

7.5”

5.5”

Max. Mantel

Depth

Min. Mantel

Depth

Max. Top Trim

Depth = 1”

3.5

A

C

E

B

D

F

G

Max.

6 1/2”

Advertising