Mobile home installation, Fuel conversion – Jotul GF 100 DV II User Manual

Page 15

Advertising
background image

15

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Tools required:
• 1/2” open ended wrench or deep-well socket, Torx T20

or slotted screwdriver, 4 mm allen wrench.

Conversion Kit Contents:
• 1, regulator tower labeled for propane
• 3, regulator tower screws
• 1, burner orifice (GF 100: #48 for NG, #56 for LP)

(GF 200: #46 for NG, 1.20 mm for LP)

• 1, pilot orifice (#51 for NG, #30 for LP)
• Label A - to be completed and applied to

the back of the stove

• Label B - apply to the stove’s Rating Plate
• Small valve label - apply to valve body

Conversion instructions are also shipped in the stove
with the conversion kit.

Mobile Home Installation

These appliances can be installed for use in a mobile

home in the U.S. and Canada provided:

1. The stove is secured to the floor of the mobile home.

Use the Jøtul Floor Bracket Kit appropriate for your
stove’s leg; see the Accessories listing on p. 29.

2. Provision must be made to secure an electrical ground

between the stove and the mobile home chassis.

3. The stove is installed in accordance with Title 24 CFR,

Part 3280- Manufactured Home Construction and
Safety Standard, in the U.S. In Canada, comply with
CSA Z240.4, Gas Equipped Recreational Vehicles and
Mobile Housing.

4. Always contact your local officials about installation

restrictions and requirements in your area.

THIS APPLIANCE MAY BE INSTALLED AS AN

OEM INSTALLATION IN A MANUFACTURED

(MOBILE) HOME AND MUST BE INSTALLED IN

ACCORDANCE WITH THE MANUFACTURER’S

INSTRUCTIONS AND THE MANUFACTURED

HOME CONSTRUCTION AND SAFETY STAN-

DARD, TITLE 24 CFR, PART 3280. THIS APPLI-

ANCE IS ONLY FOR USE WITH THE TYPE OF

GAS THAT IS INDICATED ON THE STOVE’S

RATING PLATE. A GAS CONVERSION KIT IS

PROVIDED WITH THE NORDIC QT DIRECT

VENT GAS STOVE.

THIS APPLIANCE MAY BE INSTALLED IN AN

AFTERMARKET PERMANENTLY LOCATED,

MANUFACTURED (MOBILE) HOME, WHERE

NOT PROHIBITED BY LOCAL CODES.

CET APPAREIL PEUT ETRE INSTALLE DANS

UN MAISON PREFABRIQUEE (MOBILE) DEJA

INSTALLEE A DEMEURE SI LES REGLEMENTS

LOCAUX LE PERMETTENT. CET APPAREIL

DOIT ETRE UTILISE UNIQUEMENT AVEC LES

TYPES DE GAS INDIQUES SUR LA PLAQUE

SIGNALETIQUE. NE PAS L’UTILISER AVEC

D’AUTRES GAS SAUF SI UN KITDE CONVER-

SION CERTIFIE EST INSTALLE.

Fuel Conversion

Your gas stove is shipped from the factory equipped to
burn NATURAL GAS only. If PROPANE gas is to be used as
fuel, the appliance must first be converted for use with
propane.
GF100 DV II Nordic QT: Use Propane Conversion Kit
155628, supplied with the appliance.
GF200 DV II Lillehammer: Use Propane Conversion Kit
155626, supplied with the appliance.

WARNING:

THE CONVERSION KIT IS TO BE

INSTALLED BY AN AUTHORIZED JØTUL

SERVICE TECHNICIAN IN ACCORDANCE

WITH THE MANUFACTURER’S

INSTRUCTION AND ALL CODES AND

REQUIREMENTS OF THE AUTHORITY

HAVING JURISDICTION. FAILURE TO

FOLLOW THESE INSTRUCTIONS COULD

RESULT IN SERIOUS INJURY OR

PROPERTY DAMAGE. THE QUALIFIED

AGENCY PERFORMING THIS WORK

ASSUMES RESPONSIBILITY FOR THIS

CONVERSION.

IN CANADA:

THE CONVERSION SHALL BE CARRIED

OUT IN ACCORDANCE WITH THE RE-

QUIREMENTS OF THE PROVINCIAL AU-

THORITIES HAVING JURISDICTION AND

IN ACCORDANCE WITH THE REQUIRE-

MENTS OF THE CAN1-B149.1 AND .2

INSTALLATION CODE.