Replacing the console port cable, Replacing a pim, Removing a pim – Juniper Networks J-series Services Router J2320 User Manual

Page 194: 172 replacing a pim

Advertising
background image

Table 69: Tools and Parts Required

Components

Tool or Part

All

Electrostatic bag or antistatic mat

All

Electrostatic discharge (ESD)
grounding wrist strap

PIM

Flat-blade screw-blade screwdriver,
approximately 1/4 in. (6 mm)

Chassis cover

Compact flash

Crypto Accelerator Module

DRAM modules

PIM

Power system components

Phillips (+) screwdriver, number 1
and number 2

Replacing the Console Port Cable

The RJ-45 port labeled

CONSOLE

on the Services Router's front panel allows you to

connect the router to an external management device, such as a laptop or a terminal
server. For cable specifications, see “Chassis Console Port Pinouts” on page 234.

To replace the console port cable:

1.

Locate an appropriate replacement cable and connector.

2.

Plug the Ethernet connector at either end of the cable into the console port on
the front panel (see Figure 69 on page 140 and Figure 70 on page 141).

3.

Plug the connector at the other end of the cable into the external management
device. If you are connecting to a DB-9 serial port, use the provided RJ-45 to
DB-9 serial port adapter.

Replacing a PIM

To remove or install field-replaceable Physical Interface Modules (PIMs) in a Services
Router, you must first power off the router. This section contains the following topics:

Removing a PIM on page 172

Installing a PIM on page 174

Removing a PIM

The PIMs are installed in the front of the Services Router. A PIM weighs less than
1 lb (0.5 kg).

172

Replacing the Console Port Cable

J2320, J2350, J4350, and J6350 Services Router Getting Started Guide

Advertising