Power cable warning (japanese), Dc power electrical safety guidelines – Juniper Networks J-series Services Router J2320 User Manual

Page 276

Advertising
background image

The cores in the mains lead are colored in accordance with the following code
(within the United States):

Green and yellow—Earth

Blue—Neutral

Brown—Live

When a router is equipped with two AC power supplies, both power cords (one
for each power supply) must be unplugged to completely disconnect power to
the router.

Note the following warnings printed on the AC power supply faceplate:

To completely de-energize the system disconnect maximum of 2 power
cordsets.

Apparaten skall anslutas till jordat uttag när den ansluts till ett nätverk.
[Swedish]

Power Cable Warning (Japanese)

WARNING: The attached power cable is only for this product. Do not use the cable
for another product.

DC Power Electrical Safety Guidelines

The following electrical safety guidelines apply to a DC-powered router:

A DC-powered router is equipped with a DC terminal block that is rated for the
power requirements of a maximally configured router. To supply sufficient power,
terminate the DC input wiring on a facility DC source capable of supplying at
least 8 A @ –48 VDC. Incorporate an easily accessible disconnect device into
the facility wiring. Be sure to connect the ground wire or conduit to a solid office
(earth) ground. A closed loop ring is recommended for terminating the ground
conductor at the ground stud.

In the United States, a restricted access area is one in accordance with Articles
110-16, 110-17, and 110-18 of the National Electrical Code ANSI/NFPA 70.

254

Safety Guidelines and Warnings

J2320, J2350, J4350, and J6350 Services Router Getting Started Guide