Led activity during booting, Led identification, Table 10-2 – Juniper Networks E-Series User Manual

Page 125

Advertising
background image

Understanding Status LEDs to Troubleshoot

E-Series Routers

10-3

LED Activity During Booting

When the system boots, it runs a series of tests for each module installed
in the system, and the LEDs display various configurations. Refer to the
tables in this section to understand normal and abnormal LED activity.
For troubleshooting information, see

Table 10-4

.

LED Identification

The system’s modules have two sets of status LEDs. The top set indicates
generic router and module status. The bottom set indicates
module-specific status, such as port status (line modules) or fan status
(SRP module).

The number against the port status LED on a line module corresponds to
the number of the port on the I/O module. Some line modules have more
port status LEDs than the number of ports on the I/O module. In these
cases, only the LEDs for the corresponding ports on the I/O modules are
active.

For example, an OCx/STMx line module can pair with either an OC3-4
or an OC12/STM4 I/O module. Consequently, the line module has four
port status LEDs for OC3/STM1 operation. However, only the top set of
port status LEDs are active during OC12/STM4 operation.

Table 10-2

shows the functions of the module and port status LEDs.

Table 10-2 LED identification and activity descriptions

LED Location LED Label

LED Indicator LED Color OFF to ON

ON to OFF

All modules

OK

Module status

Green

Self-test passed

Failure detected

FAIL

Module status

Red

Failure detected

Diagnostic test running

ONLINE

Module status

Green

Module online

Module offine

All modules

REDUNDANT Redundancy

Green

See

Redundancy Status

later in this chapter.

Note: The REDUNDANT LED on the cOCx/STMx,
FE-8, GE/FE, HSSI, OCx/STMx, and X.21/V.35 line
modules is nonfunctional.

SRP module

POWER A
OK

Power

Green

Power online on source
A

Power off

POWER B
OK

Power

Green

Power online on source
B

Power off

FAN OK

Fan

Green

Fan online

Fan failure

FAN FAIL

Fan

Red

Fan failure

Fan online

LINK

Ethernet

Green

Ethernet link up

Ethernet link down

ACTIVITY

Ethernet

Green

Blinks when Ethernet
traffic on link

No Ethernet traffic on link