Installing the i/o modules, Installing the i/o modules -15, Figure 5-7 – Juniper Networks E-Series User Manual

Page 75

Advertising
background image

Installing Components for Line Module Redundancy

E-Series Routers

5-15

Figure 5-7 Installing a redundancy midplane

Installing the I/O Modules

To install the I/O modules in a redundancy group:

1

Install the redundancy I/O module in the lowest-numbered slot of
the redundancy group.

Caution: When setting up a redundancy group with line modules, be sure to install
the redundancy I/O module in the lowest-numbered slot of the redundancy group.
It is possible to install the redundancy I/O module in other slots; however, doing so
may damage other I/O modules connected to the redundancy midplane.

2

Install the corresponding I/O module for the line module of each slot
in the redundancy group. (See

Installing a Line Module or an I/O

Module

, earlier in this chapter.)

3

Cable each module to provide a path to the remote interface (see

Chapter 6, Cabling E-Series Routers

).

Redundancy

midplane

g013748