Erx-7xx models specifications, Erx-7xx models specifications -3 – Juniper Networks E-Series User Manual

Page 139

Advertising
background image

ERX-7xx Models Specifications

E-Series Routers

11-3

ERX-7xx Models Specifications

Telecommunications
Certification

ACA TS 016-1997

CTR13 – Commission Decision of 9 July 1997 on a common technical
regulation for attachment requirements for terminal equipment interface for
connection to 2048 kbit/s digital structured ONP leased lines: 97/521/EC –
OJ No. L215 Vol. 40, August 1997

CTR24 – Commission Decision of 9 September 1997 on a common
technical regulation for attachment requirements for terminal equipment
interface for connection to 34 Mbit/s digital unstructured and structured
leased lines: 97/639/EC – OJ No. L271 Vol. 40, 3 October 1997

FCC PART 68

IECS-003 Issue 3 Class A

PD7024 – Essential requirements for terminal equipment intended for
connection to unstructured digital leased circuits of the public
telecommunications network using a CCITT recommendation G,703
interface at a rate of 2048 kbit/s with a 75 ohm unbalanced presentation,
1994

RTTE Directive (1999/5/EEC)

a.If the voltage rises above –40 VDC, the system will power off. The system will not power on again until the input

voltage reaches –43 +/– 0.5 VDC.

Table 11-1 ERX-14xx models specifications (continued)

Category

Specification

Table 11-2 ERX-7xx models specifications

Category

Specification

Weight
Chassis only
Chassis fully configured

22 lb

9.9 kg

46 lb

20.7 kg

Dimensions

10.5 (H) x 19 (W) x 16 (D) inches; 26.67 x 48.26 x 40.64 cm

Environmental Requirements
Ambient operating temperature

Ambient operating humidity

Ambient storage temperature
Ambient storage humidity

NEBS GR-63-CORE compliant

Long term: 41

°

to 104

°

F (5

°

to 40

°

C)

Short term: 23

°

to 122

°

F (–5

°

to 50

°

C)

Long term: 5% to 85% (noncondensing)
Short term: 5% to 95% (noncondensing)

–40

°

to 158

°

F (–40

°

to +70

°

C), 95% relative humidity

5% to 95% (noncondensing)

Heat Dissipation

1400 W, 4780 BTU/hour maximum

Space Requirements

3 feet (90 cm) behind router or rack

Do not block air vents on sides of the router.

Do not place equipment that exhausts hot air to left on the right of the router.

Be aware that router exhausts hot air from its left side.

Advertising