INSTALLING THE OPTIONAL

WALL THERMOSTAT OR REMOTE:

When installing a wall mounted thermostat to

the Allagash, it must be a 750 millivolt DC two-

wire circut thermostat. The thermostat should

be placed in the same room as the heater, typically

5’ off the floor. Avoid drafty areas or any area

that may effect the accuracy of the thermostat.

The thermostat should be connected to the

Allagash using a minimum of 16 gauge wire with

a maximum length of 35 feet of wire.

Connect the two thermostat wire leads to the two

lower terminals on the terminal block located

directly above the ignitor button. Do not

overtighten the connections. IT IS NOT

NECESSARY TO DISCONNNECT ANY

OTHER WIRES. See Figure 12.

For the thermostat to work the On/Off/T-Stat

switch on the back of the stove must be in the

T-stat position, and the pilot light must be running,

as it is the power source for the thermostat.

At the thermostat, the two wires should be

connected to the two connections screws on the

thermostat base plate per the manufacturer’s

instructions.

Remote: When using a remote, the remote

receiver should be wired to the terminal block

the same way the thermostat would be. See the

instructions above.

SPILL SWITCH:
The Allagash B-Vent gas stove is equipped with a

vent “

SPILL

SWITCH

”. This switch stops gas flow

to the main burner in the event that the appliance

is not vented or if the venting is blocked.

The spill switch is an important safety device

located on the draft hood of the appliance and is

wired directly to the thermocouple (power source

for the stove). The “spill switch” is a bimetal

sensor that is heat sensitive. In the event that

the venting is not carrying the exhaust up and

out, the heat from the exhaust will trigger the

switch and stop the electrical current to the valve;

thereby stopping gas flow to the main burner.

Spillage: Condition of flue gases failing to exit

the venting system properly and instead flowing

out of the relief opening of the draft hood and

into the dwelling. Condition calls for

immediate examination of the appliance and

venting system and corrective action.

Source: HEARTH- Gas Training Manual

Spillage usually occurs due to incorrct vent size,

or incorrct installation. Be sure to read all of the

installation requirements addressed in this manual

for the proper and safe installation of your

Allagash B-Vent gas stove.
Unexplained outages can be the result of the “spill

switch”. If you experience unexplained outages,

contact your local Jøtul dealer for assistance.

ANY SERVICE TO THE SAFETY SPILL SWITCH

MUST BE DONE BY A QUALIFIED SERVICE

AGENCY.

CAUTION:

LABEL ALL WIRES PRIOR TO DISCONNECTION

WHEN SERVICING THE CONTROLS. WIRING

ERRORS CAN CAUSE IMPROPER AND

DANGEROUS OPERATION. ALWAYS VERIFY

PROPER OPERATION AFTER SERVICING THE

APPLIANCE.

ATTENTION:

AU MOMENT DE L’ENTRETIENDES

COMMANDES, ETIQUETEZ TOUS LES FILS

AVANT LE DEBRANCHEMENT. DES ERREURS

DE CABLAGE PEUVENT ENTRAIUN

FONCTIONNEMENT

INADEQUAT

ET

DAGEREUX.

17

Figure 12

Advertising