THIS APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY OR FLUE

SERVING ANY OTHER APPLIANCE OF

ANY KIND.

LOCATION:

In selecting the location, the aesthetic and

functional use of the appliance are primary

concerns; However, proper venting systems and

access to the fuel supply are also important issues.

Due to the high surface temperatures of the

Allagash, always consider the proximity of traffic

ways, furniture, draperies, etc.

This appliance may be located on or near

conventional construction materials.

HOWEVER,

always maintain the proper clearances to

combustibles, as this provides adequate

ventilation air around the appliance.

The following clearances and hearth requirements

are the minimum requirements when installing

the Allagash gas stove near or on combustible

surfaces. Always provide adequate access around

the appliance for servicing and proper operation.

A combustible surface is anything that can burn

(i.e. sheet rock, wall paper, wood, fabrics etc.).

These surfaces are not limited to those that are

visible and also include materials that are behind

non-combustibles.

If you are not sure of the combustible nature of

a material, consult your local fire officials.

Remember, “Fire Resistant” materials are

considered combustible: they are difficult to

ignite, but will burn. Also, “fire-rated” sheet rock

is considered combustible.

The Allagsh B-Vent gas stove is not to be

connected or installed using any warm air duct

system.

Always maintain the proper clearances to the

appliance for the proper flow of combustion and

ventilation air to the stove.

Hot Surfaces

The Allagash gas stove will, during normal

operation, reach high surface temperatures

therefore:

·

Due to the high operating temperatures this

appliance should be located out of traffic

and away from furniture and draperies.

·

Children and adults should be alerted to the

hazards of high surface temperatures and

should stay away to avoid burns or clothing

ignition.

·

Young children should be supervised while

they are in the same room as the Allagash

gas stove.

·

Clothing or other flammable materials

should not be placed ON or NEAR the

Allagash gas stove.

·

Surveiller les enfants. Garder les vetements,

les meubles, l’essence ou autres liquides a

vapeur inflammables loin de l’appareil.

·

NEVER store or use gasoline or any other

flammable vapors or liquids in the vicinity

of the Allagash gas stove.

·

Never burn any other materials in your

Allagash gas stove, it is strictly designed for

use with natural gas or propane fuel ONLY.

·

Any safety screen, glass or guard removed

for servicing the appliance must be replaced

prior to operating the appliance.

Blower/Electrical Hazard

When the Allagash gas stove is installed with the

optional forced air Blower Kit (part #129161) the

stove must be electrically grounded in accordance

with local codes or, in the absence of local codes,

with the current NFPA 70- National Electrical

Code or CSA C22.1-Canadian Code.

The Allagash Blower Kit is already supplied with

a three-prong (grounding) plug for protection

against shock hazard and should be plugged

directly into a properly grounded three-prong

receptacle.

DO NOT CUT OR REMOVE THE

GROUNDING PRONG FROM THE PLUG.

Always unplug the Blower when performing

routine service to the Allagash gas stove.

5