Venting configurations for the allagash b-vent – Jotul GF 3 BV User Manual

Page 9

Advertising
background image

9

Maximum

horizontal

offset

anywhere in

venting

configuration

is 4 feet.

Minimum

chimney height

off draft hood

= 7 feet.

Listed B-Vent

termination cap

required.

Listed B-Vent

termination cap

required.

Minimum

chimney height

off draft hood

= 7 feet.

Maximum total

horizontal offset

anywhere in

venting

configuration is

4 feet.

45° or 90°

elbow

45° or 90°

elbow

45° or 90°

elbow

45° or 90°

elbow

VENTING CONFIGURATIONS FOR THE

ALLAGASH B-VENT

Maximum horizontal offset anywhere in

venting configuration; rear vent or top vent

directly on the stove or further up

45° or 90° elbows = 4 feet.

Maximum horizontal offset anywhere in

venting configuration; rear vent or top vent

directly on the stove or further up

45° or 90° elbows = 4 feet.

Maximum # of elbows;

90°= three

45°=four

Listed B-Vent termination cap always required.

NOTE:

When installing

at an altitude

above 2000’ the

minimum

vertical rise

becomes 12’

from the draft

hood.

NOTE:

When installing

at an altitude

above 2000’ the

minimum

vertical rise

becomes 12’

from the draft

hood.

Maximum

chimney height

off draft hood

= 35 feet.

Minimum

chimney height

off draft hood

= 7 feet.

Listed B-Vent

termination cap

required.

Minimum chimney on the Allagash

B-Vent top vent or rear vent = 7 feet.

NOTE:

When installing

at an altitude

above 2000’ the

minimum

vertical rise

becomes 12’

from the draft

hood.

Maximum total

horizontal

anywhere in

venting

configuration

is 4 feet.

Minimum

chimney height

off draft hood

= 7 feet.

Listed B-Vent

termination cap

required.

45° or 90°

elbow

45° or 90°

elbow

NOTE:

When installing

at an altitude

above 2000’ the

minimum

vertical rise

becomes 12’

from the draft

hood.