CHECKING THE SYSTEM:

1. PURGING THE GAS LINE: When lighting

the appliance for the first time it will take a few

moments to clear the gas line of air. Once this

purge is complete, the appliance will operate as

described in the lighting instructions located on

the stove’s rating plate and the back cover of this

manual. All subsequent lightings of the stove

will not require such purging of the gas line.

2.

PILOT FLAME: The pilot flame should be

steady, not lifting or floating. The flame should

be blue in color around the pilot hood, with traces

of yellow toward the outer edges.

It is imperative that the pilot flame engulf the

top 3/8” of the thermopile (power generator) and

the top 1/8” of the quick drop out thermocouple.

The pilot flame should project out of the pilot

hood 1” at all three ports. See Figure 13.

3. BURNER ADJUSTMENT: The Jøtul

Allagash gas stove is equipped with a variable

gas control valve. This valve provides easy

adjustment of the flame height appearance and

heat output. To adjust the flame between the HI

and LO setting, rotate the HI/LO knob, located

in the center of the valve face. Flame height will

adjust approximately 1.0” to 1.5” between the

HI and LO settings.

See Figure 14.

NO SMOKE OR SOOT SHOULD BE

PRESENT. CHECK LOG PLACEMENT IF

ANY SOOT OR SMOKE IS DETECTED. IF

SOOT OR SMOKE PERSIST, THE AIR

SHUTTER MAY NEED TO BE ADJUSTED.

See Air Shutter/Flame Appearance section of this

manual for proper air shutter settings and

adjustments (page 14). Note: the more offsets

on the vent system, the greater the need for an

air shutter adjustment.

CAUTION:

DO NOT ATTEMPT TO ALTER THE

FLAME APPEARANCE BY

POSITIONING THE GAS VALVE IN

ANY OTHER POSITION OTHER

THAN THE FULL “ON” POSITION.

Flame appearance on the high setting after

approximately 15 to 20 minutes burning.

5”-6”

3”- 4”

3”- 4”

WARNING:

AIR SHUTTER ADJUSTMENTS

SHOULD ONLY BE PERFORMED BY A

QUALIFIED PROFESSIONAL SERVICE

TECHNICIAN.

Figure 14

18

(25mm)

3/8”

(8mm)

Min.

1/8”

(3mm)

Min.

Thermocouple

Ignitor

Thermopile

Pilot Hood

Figure 13.

Pilot Assembly

Air Inlet Shutter

Burner Tube