Smith Cast Iron Boilers GB300 User Manual

Page 15

Advertising
background image

GB300 BOILER INSTALLATION AND OPERATION INSTRUCTIONS

Page 15

Figure 18

Manifold Attachments

Locate the Burner Box. It is marked with a number from
72724 to 72731. Install three burner tubes in the base,
one on each end and one in the middle. Slide the closed
end of the burner tube through the slot in the burner
base rear panel. The notch in the burner must engage
the burner base rear panel, Figure 19.

Figure 19

Burner Tube Installation

Adjust the manifold and base so the burner tube orifice
bracket is approximately in the middle of the orifice on
all three burners, Figure 20.

Figure 20

Burner Tube Adjustment

NOTE: The base front panels bolt to the inside of the
front base splice channel, Figure 15.

Figures 15

Base Front Panel Detail

Use a spirit level to plumb the front and rear panels
before tightening the nuts and bolts, Figure 16.
Temporarily attach the manifold brackets and manifold,
Figures 17 and 18.

Figure 16

Plumbing Base

Figure 17

Manifold Bracket Attachment

Notch

Notch
Engaged

Advertising