Smith Cast Iron Boilers GB300 User Manual

Page 25

Advertising
background image

GB300 BOILER INSTALLATION AND OPERATION INSTRUCTIONS

Page 25

Clean Out Covers
The clean out covers and mounting hardware are
packaged in the Burner Box with a number from 72724
to 72731
on it, Figure 52

Figure 52

Clean Out Cover & Hardware

.

Arrange the clean out cover(s) in front of the boiler so
the mounting stud locations can be determined. Attach
the mounting studs to the heat exchanger as shown in
Figures 53 and 54.

Figures 53

Clean Out Cover Bolt Assembly

Figures 54

Clean Out Cover Bolt Location

Place the foil-backed insulation over the studs with the
foil against the boiler, Figure 55. Install the clean out
cover(s) so the bent edges face out and hand tighten
the wing nuts so the insulation is fully compressed,
Figure 56.

Figure 55

Clean Out Cover Insulation

Figure 56

Clean Out Cover Installation

Advertising