2) element width 1 (3) bar code height, 4) setting hri on and off 1 – Seiko Group BP-9000 User Manual

Page 79

Advertising
background image

(2) Element width: DC4 DC4 E

Format:

ASCII

DC4

DC4

E

n1 n2

Hex

14

14

45

n1 n2

Decimal

20

20

69

n1 n2

Function:

Specifies the n2/120” or n2/180” width of the element n1.
(1

n2

127)

120” or 180” is specified with the DC4 DC4 D command.

n1 = 0: Narrow bar

3: Wide space

1: Wide bar

4: Inter-character gap

2: Narrow space

The narrow bar width or narrow space is used as the element width for

Code 93, Code 128, EAN-8, EAN-13, UPC-A, and UPC-E.

One element width of bar 1: Narrow bar width

One element width of space 1: Narrow space width

The midium bar or wide space width is used as the midium element

width for Code 11. The wide element width is (wide bar width x 2 -

narrow bar width).

This setting is not valid for Postnet.

The inter-character gap means the space between each set of codes of a

bar code which begins with a bar and ends with a bar.

(3) Bar code height: DC4 DC4 H

Format: ASCII

DC4

DC4

H

n

Hex

14

14

48

n

Decimal

20

20

72

n

Function: Sets the bar code height to n/12”. (0

n

120)

The currently set line feed pitch serves as the bar code height when

is set to 0. This setting is not valid for Postnet.

(4) Setting HRI on and off: DC4 DC4 I

Format: ASCII

DC4

DC4

I

n

Hex

14

14

49

n

Decimal

20

20

73

n

Function: Specifies whether or not to print an HRI. Also specifies the

HRI printing position if an HRI is to be printed.

n = 0: HRI not printed.

1: HRI printed below the bar code symbol.

2: HRI printed above the bar code symbol.

No HRI printed for Postnet or Element regardless of this setting.