5) hri font 2 (6) check character, 7) starting the bar code data sequence 2 – Seiko Group BP-9000 User Manual

Page 80

Advertising
background image

(5) HRI font: DC4 DC4 F

Format:

ASCII

DC4

DC4

F

n

Hex

14

14

46

n

Decimal

20

20

70

n

Function: Selects the font of printing the HRI.

n = 0: Currently selected font

1: OCR-A

2: OCR-B

This setting is not valid for Postnet or Element.

(6) Check character: DC4 DC4 C

Format:

ASCII

DC4

DC4

C

n

Hex

14

14

43

n

Decimal

20

20

67

n

Function: Specifies whether to add a check character automatically.

n = 0: No check character is added. (If a check character is needed, the

user must send bar code data.)

1: A check character is added. (The check character is not printed

in the HRI when Code 93 or Code 128 is selected.)

If the Codabar or Element is selected, no check character is added regardless of

this setting.

The following shows the methods of determining the check characters and bar code

types. (For details, see “Calculating the check character” below.)

Modulus 10

Industrial 2 of 5, Interleaved 2 of 5, Matrix 2 of 5, EAN, UPC,

Postnet

Modulus 11

Code 11 (Dual Check character)

Modulus 16

Codabar

Modulus 43

Code 39

Modulus 47

Code 93 (Dual Check character)

Modulus 103 Code 128

(7) Beginning of the bar code data sequence: ESC SI

Format:

ASCII

ESC

SI

Hex

1B

0F

Decimal

27

15

Function: Indicates the beginning of a bar code data sequence.

Data between this and the end command of the bar code data sequence

is regarded as bar code data.

This command is valid only when #27 BARCODE/LABEL MODE is

set to MODE 2 in the EXTENDED SETUP MODE.

72

9. Bar code and enlarged character

Advertising