Seiko Group BP-9000 User Manual

Page 81

Advertising
background image

(8) End of the bar code data sequence: ESC SO

Format:

ASCII

ESC

SO

Hex

1B

0E

Decimal

27

14

Function:

Indicates the end of a bar code data sequence.

This command is valid only when #27 BARCODE/LABEL MODE is set

to MODE 2 in the EXTENDED SETUP MODE.

(9) Bar code data sequence: DC4 DC4 B

Format:

ASCII

DC4

DC4

B

n

d1

d2 ... dk

Hex

14

14

42

n

Decimal

20

20

66

n

Function: Specifies the number (“n”) of data to be regarded as bar code data.

00

n

68

00

dk

255

00

k

68

If the Element is selected; 0

n, dk, k

255

This comand is valid when #27 BARCODE/LABEL MODE is set to MODE1 or

MODE2 in the EXTENDED SETUP MODE.

(10) Printing density: DC4 DC4 D

Format:

ASCII

DC4

DC4

D

n

Hex

14

14

44

n

Decimal

20

20

68

n

Function:

Specifies the density of printing bar code symbols (in the horizontal

direction).

Specifies the unit of element width.

n = 0:

Bar code symbols are printed at 120 dpi. (Default value)

1:

Bar code symbols are printed at 180 dpi.

If a bar code is rotated by 90 or 270 degrees using the DC4 DC4 R (bar code

rotational angle) command, a bar code is printed at 120 dpi horizontally and 180

dpi vertically.

(11) Guard bar expansion: DC4 DC4 G

Format:

ASCII

DC4

DC4

G

n

Hex

14

14

47

n

Decimal

20

20

71

n

Function: Specifies whether or not to expand EAN or UPC guard bars.

n = 0: Guard bars are not expanded.

1: Guard bars are expanded. (Default value)

9. Bar code and enlarged character