8. INSTALLATION INSTRUCTIONS

Minimum height
from floor level
5 ft.

Indoor Unit

Wall

Floor level

2205_M_S

2)

Selecting the Installation Site

AVOID:

areas where leakage of flammable gas may
be expected.
places where large amounts of oil mist
exist. (Fig. 2)
direct sunlight.
locations near heat sources which may
affect performance of the unit.
locations where external air may enter the
room directly. This may cause “sweating”
on the air discharge ports, causing them to
spray or drip. (Fig. 3)
locations where the remote control unit will
be splashed with water or affected by
dampness or humidity.

DO:

select an appropriate position from which
every corner of the room can be uniformly
air-conditioned.
select a location that will hold weight of the
unit.
select a location where the tubing and drain
pipe have the shortest run to the outside.
(Fig. 2)
allow room for operation and maintenance
as well as unrestricted air flow around the
unit. (Fig. 3a and 3b)
Install the unit within the maximum
elevation difference above or below the
outdoor unit and within a total tubing length
from the outdoor unit as detailed in Table 1
and Fig. 1 on the previous page.

Indoor Unit

Fig. 2

For stable operation of
the air conditioner, do
not install wall-mounted
type indoor units less
than 5 ft. from floor
level.

CAUTION

Drain hose

Indoor unit

Outside drainage

2203_M_S

6 inches

min.

6 inches

min.

6 inches min.

INDOOR UNIT

Front View

2204_M_S

Fig. 3a

Fig. 3b